Infinity ID2 2-8 Zone Fire Alarm Panel

548,670.00

  • Ability to wire in Radial or Loop modes (selectable on panel)
  • Panel shows exact device in fire, “Bedroom 1”, “Main Office”, etc.
  • Verify alarms to reduce false alarms

Summary

Zeta Alarm Systems is proud to introduce the most advanced 2 wire system on the market. We can now provide a system that gives all of the benefits associated with a ‘2 Wire’ installation (less cable, quicker installation, cost savings on labour/product) and has the facility to ‘I.D.’ the devices.

The Infinity ID2 can be used for new installations, as a retro-fit for any conventional system or as a replacement for existing 2 wire systems when the extra features are deemed to be desirable/necessary. This is possible because the Infinity ID2 devices sit on radial circuits, thus making it easy to ‘upgrade’ a system with the facility to I.D. devices without the need to rewire.

Key Features

  • One man walk test facility
  • Ability to isolate zones/sounder circuits
  • High visibility blue LCD screen as standard
  • Deeper version panel available if larger batteries required
  • Full range of zone powered devices available
  • Auto configuration for easy set up
  • Safer than a traditional 2 wire/conventional system as it tells you exactly where the event is – no time wasted searching a whole zone
  • System already wired as a loop? No problem! Just select ‘Loop Mode’ in the panel

Specifications

  • Detection Zones: 2-8 Zones
  • Mains Voltage: 230V AC +10% /- 15% @ 50/60 Hz
  • System Voltage: 29V DC Nominal (19 – 30 V)
  • Sounder Alarm Output: Loop Powered Sounders 2 x Conventional sounder circuits 28V nominal,150mA (20-30V DC)
  • Fault Output: 1 x Fault Relay SELV@1A (Normaly Energised
  • Fire Relay Output: 1 x Fire Relay SELV@1A
  • Zone Capacity: 15 Devices Per Zone
  • Max. No. of Detection Circuits: Radial Mode – 8 Radial Circuits Loop Mode – 1 Loop Circuit
  • Max. Loop Sounder Quantity: 80 Sounders
  • Repeater Connection: RS485
  • Dimensions (mm): 370(W) x 311(H) x 113(D)

FAQ

Can the ID2 have a repeater connected and if so how would you cable between them?

The Infinity ID2 can have upto 8 active repeaters.

The repeaters are powered from the ID2 panel, so is connected via 4 cores: 2 x power and 2 x data. The first 2 repeaters can be powered from the panel. Subsequent repeaters would need an external power supply.

Each repeater can be selectively configured to determine which commands it will send to the network. EG to allow some repeaters to reset the system, and others to not reset the system. Each Repeater can also be configured to run in a different language (Although any device labels entered by the installer will just be in the language entered) The repeater shows Alarms and faults from the fire panel. It does not show disablements or test mode events. The repeater can be configured to start panel sounders, stop panel sounders, Silence panel Buzzers and reset the panel. The repeater can not interrogate panel configuration or device status. The repeater can not select disablements or test mode.

Please see diagram showing the connection of a repeater to the main panel.

Downloads

Weight 3 kg
Detection Zones

2 Zone, 4 Zone, 8 Zone

Enclosure

Standard Enclosure, Metal Enclosure

Device Type

Control Panel

Protocol

Infinity ID2